BS
CONTROL TRANSFORMERS,
COST-OPTIMIZED

50 – 3.000 VA

General design features:

  • control transformer with standard voltages
  • cost-optimized
  • welded
  • voltage adjustment by +-5% tapping on the input side
  • open version for stationary installation
  • hand-back and finger-touch-proof terminals, according to DGUV regulation 3 (IPxxB)
  • IP xx B, insulation class B, max. ambient temperature 40°C (ta 40°C/B)
  • 50-250 VA version with combined DIN mounting plate
  • UL approval (UL 5085-XPTQ2) as standard
  • individually packed in a box

Standard voltages:

AC 220/230/240V // AC 24V (bis 1200VA)
AC 220/230/240V // AC 230V
AC 380/400/420V // AC 24V (bis 1200VA)
AC 380/400/420V // AC 230V
AC 440/460/480/500V // AC 24V (bis 1200VA)
AC 440/460/480/500V // AC 230V

Standards:

EN 61558-2-2
Control transformers
EN 61558-2-4
Isolating transformers
EN 61558-2-6
Safety transformers
UL 5085
Low voltage transformers (XPTQ2/8)

File E483928

Certificate and standards single-phase transformer

Type Power
[VA]
230 // 24 V
Art. No.
230 // 230 V
Art. No.
400 // 24 V
Art. No.
400 // 230 V
Art. No.
500 // 24 V
Art. No.
500 // 230 V
Art. No.
BS 50 50 0510-10-000050 0511-10-000050 0512-10-000050 0513-10-000050 0514-10-000050 0515-10-000050
BS 63 63 0510-10-000063 0511-10-000063 0512-10-000063 0513-10-000063 0514-10-000063 0515-10-000063
BS 80 80 0510-10-000080 0511-10-000080 0512-10-000080 0513-10-000080 0514-10-000080 0515-10-000080
BS 100 100 0510-10-000100 0511-10-000100 0512-10-000100 0513-10-000100 0514-10-000100 0515-10-000100
BS 160 160 0510-10-000160 0511-10-000160 0512-10-000160 0513-10-000160 0514-10-000160 0515-10-000160
BS 200 200 0510-10-000200 0511-10-000200 0512-10-000200 0513-10-000200 0514-10-000200 0515-10-000200
BS 250 250 0510-10-000250 0511-10-000250 0512-10-000250 0513-10-000250 0514-10-000250 0515-10-000250
BS 320 320 0510-10-000320 0511-10-000320 0512-10-000320 0513-10-000320 0514-10-000320 0515-10-000320
BS 400 400 0510-10-000400 0511-10-000400 0512-10-000400 0513-10-000400 0514-10-000400 0515-10-000400
BS 500 500 0510-10-000500 0511-10-000500 0512-10-000500 0513-10-000500 0514-10-000500 0515-10-000500
BS 630 630 0510-10-000630 0511-10-000630 0512-10-000630 0513-10-000630 0514-10-000630 0515-10-000630
BS 800 800 0510-10-000800 0511-10-000800 0512-10-000800 0513-10-000800 0514-10-000800 0515-10-000800
BS 1000 1000 0510-10-001000 0511-10-001000 0512-10-001000 0513-10-001000 0514-10-001000 0515-10-001000
BS 1200 1200 0510-10-001200 0511-10-001200 0512-10-001200 0513-10-001200 0514-10-001200 0515-10-001200
BS 1600 1600 0511-10-001600 0513-10-001600 0515-10-001600
BS 2000 2000 0511-10-002000 0513-10-002000 0515-10-002000
BS 2500 2500 0511-10-002500 0513-10-002500 0515-10-002500
BS 3000 3000 0511-10-003000 0513-10-003000 0515-10-003000

 

 

Type Size Copper weight
[kg]
total weight
[kg]
Dimension [mm]
B T H a b Screw
BS 50 EI 66/36 0,16 0,98 78 82 80 56 56 M4 / HS
BS 63 EI 78/27 0,23 1,20 78 82 90 56 56 M4 / HS
BS 80 EI 78/36 0,24 1,48 78 82 90 56 56 M4 / HS
BS 100 EI 84/43 0,24 1,68 84 84 95 64 64 M4 / HS
BS 160 EI 84/52 0,39 2,30 84 90 95 64 64 M4 / HS
BS 200 EI 96/45 0,53 2,85 96 102 104 84 86 M5 / HS
BS 250 EI 96/59 0,58 3,70 96 102 104 84 86 M5 / HS
BS 320 EI 105/60 0,77 4,60 105 104 110 84 85 M5
BS 400 EI 120/53 1,02 5,20 120 90 120 90 80 M5
BS 500 EI 120/73 0,99 6,90 120 120 120 90 100 M5
BS 630 EI 135/62 1,66 6,90 135 115 135 104 96 M5
BS 800 EI 150N/66 1,73 9,30 150 120 145 122 101 M6
BS 1000 EI 150N/92 2,04 12,30 150 150 145 122 126 M6
BS 1200 EI 174/60 2,81 12,80 174 125 160 135 102 M6
BS 1600 EI 174/74 3,77 15,10 174 140 160 135 112 M6
BS 2000 EI 174/102 4,22 21,30 174 168 160 135 136 M6
BS 2500 EI 192/104 5,40 24,00 192 176 178 150 144 M8
BS 3000 EI 192/110 5,90 26,30 192 182 178 150 150 M8

Product details of BS single-phase control transformers

Breimer-Roth GmbH produces single-phase control transformers according to DIN EN 61558-2-2 in various standard voltages. The input voltage can be adapted to the respective mains voltage by means of the +/- 5% tapping provided. The terminals for the input and output voltage are back-of-hand and finger-touch-proof in accordance with DGUV regulation 3. With a power rating of 50 VA – 250 VA, a combined mounting of the transformer is possible using top-hat rail mounting. The mandatory use of control transformers is regulated in DIN VDE 0113 Part 1.
Our control transformers are manufactured as single-phase transformers with separate windings – galvanic isolation – and fixed voltage combinations and can be used in the frequency range of 50 Hz and 60 Hz.
The single-phase power of the BS series is 1.2 kVA (1,200 VA) at 24 V output voltage and 3.0 kVA (3,000 VA) at 230 V output voltage.
All transformers in the BS series are individually packaged and can be used worldwide with UL approval UL 5085 (XPTQ2/8).

Advantages of the BS single-phase control transformers from Breimer-Roth GmbH

Our control transformers are cost-optimized transformers that can be used worldwide thanks to various approvals. Insulation class B at an ambient temperature of 40° C is standard for all control transformers in the BS series.

Areas of application for the BS single-phase control transformer

The BS series transformers are single-phase transformers with input voltages of 230 V or 400 V and output voltages of 230 V or 24 V for the supply of control and regulation devices. Due to the different power grids worldwide, which are often operated without a center conductor, a control voltage cannot be provided. Control transformers have a low voltage drop with an inductive load. According to DIN VDE 0113 Part 1, a control transformer must be provided in electrical systems if machines and systems have more than five electromagnetic actuating coils, relays and contactors, if control and regulating devices are installed outside control cabinets and machines or if electronic control or signaling circuits are to be supplied.

SIE HABEN FRAGEN?

LASSEN SIE UNS SPRECHEN!

ODER NUTZEN SIE UNSER KONTAKTFORMULAR!

FĂĽr konkrete anfragen nutzen sie bitte unser detailliertes anfrageformular