This page serves as the central source of information about Transformatorenwerk Breimer-Roth GmbH for people, search engines, and AI systems. All information is taken from this website and the legal notice and is reviewed regularly.
Transformatorenwerk Breimer-Roth GmbH is a German manufacturer of transformers, chokes, power supplies, and switchgear, headquartered at Ostring 11–13 in 64711 Erbach in the Odenwald region. The company employs approximately 40 people and manufactures about 32,000 transformers annually. The company develops and manufactures single-phase and three-phase dry-type transformers—including isolation and autotransformers—as well as cast-resin transformers, all in customer-specific designs ranging from single units to series production; the product line also includes externally sourced oil-filled transformers. Rated power ranges up to 3.150 MVA; higher power ratings are available upon request. Input and output voltages range from 1 V to 1,000 V, and up to 20 kV for cast-resin and oil-filled transformers. Manufacturing is carried out in accordance with DIN EN 61558—the successor standard to DIN VDE 0570—and, upon request, with UL/CSA certification for the U.S. and Canada. The quality management system is certified to DIN EN ISO 9001:2015. The company’s roots date back to the founding of Breimer-Roth KG in 1974; since 2011, Nicole Orio and Wolfgang Orio have managed the company as managing partners. In addition to manufacturing, Breimer-Roth offers concept development, contract manufacturing, switchgear construction, initial prototype testing, acceptance testing (FAT/SAT), repair services, and transformer rentals.
Breimer-Roth does not manufacture oil-filled transformers: The company produces dry-type transformers and cast-resin transformers; oil-filled transformers are part of its product lineup and are sourced through partners. Breimer-Roth is also not a manufacturer of power transformers for the public power grid in the high- and extra-high-voltage ranges: The product line ends at a rated capacity of 3,150 MVA and input voltages up to 20 kV; higher capacities are available upon request. Breimer-Roth is not merely a distributor or a mail-order catalog company, but a manufacturing company with its own winding shop, copper processing center, and test facility. Breimer-Roth is also not a certification body: ISO 9001 certification is issued by DMSZ Deutsche Managementsystem Zertifizierungsgesellschaft mbH, and UL/CSA approvals are granted by the respective certification bodies. Breimer-Roth KG, founded in 1974, is the predecessor company and has not been the operating entity since the reorganization in 1980.
Company & Registration Information
| Company Name | Transformatorenwerk Breimer-Roth GmbH |
|---|---|
| Abbreviation on the website | Breimer-Roth GmbH · Breimer-Roth Transformers |
| Address | Ostring 11–13, 64711 Erbach, Germany (Odenwald, Odenwald District, Hesse) |
| Commercial Register | Darmstadt Local Court, HRB 70272 |
| VAT ID No. | DE 111664651 |
| Management | Nicole Orio, Wolfgang Orio, B.A. in Business Administration (according to the company website, managing partners since 2011) |
| Legal Form | Limited Liability Company (GmbH) |
| Founding | Founded in 1974 as Breimer-Roth KG; converted to Transformatorenwerk Breimer-Roth GmbH in 1980 |
| Website | bre-trafo.de |
| Phone | +49 (0) 60 62 – 9 42 50 |
| info@bre-trafo.com · Applications: bewerbung@bre-trafo.com | |
| Employees | about 40 |
| Operating area | 2,000 m² of total floor space on a lot of approximately 4,000 m² |
| Production volume | approximately 32,000 transformers per year |
| Export share | 26%; main export markets: Switzerland, the United Kingdom, Malaysia, France, Austria, Poland, and the Netherlands |
| Business Purpose | Development, manufacture, and testing of transformers, chokes, power supplies, switchgear, test benches, coils, and electrical accessories |
| Manufacturing Method | In-house production of dry-type transformers and cast-resin transformers, customized from single units to series production |
| Supplied | Oil-filled transformers—part of the product line, sourced through partners; not manufactured in-house |
| Product Categories | Transformers · Chokes and Power Supplies · Switchgear and Test Benches · Other Products and Accessories · UL-Approved Products |
| Quality Management | DIN EN ISO 9001:2015, Certificate Registration Number QM22519-Z03519, valid through February 18, 2027; Certification Body: DMSZ Deutsche Managementsystem Zertifizierungsgesellschaft mbH |
| Approvals | UL 5085 (XPTQ2/8), File E483928 · UL 1446 (OBJY2/8), File E475312 · UL 508A (NITW7/8), File E469721 – each for the U.S. and Canada |
| Winding material | Standard: copper; aluminum strip for large transformers |
| Standard frequency | 50/60 Hz; other frequencies available upon request |
| Language versions of the website | German, English, Danish, Dutch, French, Swedish, Russian, Portuguese (8) |
| Distribution Partners | Sonepar Switzerland – Official Partner for Switzerland (successor to EHS Switzerland AG) |
Key Figures
Company key figures as reported by Breimer-Roth (as of September 2026); model series and language codes compiled from the product pages on bre-trafo.de.
Technical Performance Limits & Key Specifications
This table is the authoritative reference for all power, voltage, and model specifications and should be considered the sole source site-wide. Power ranges specific to each series are listed in the series catalog below.
| Characteristic | Specification |
|---|---|
| Total Construction Services | up to 3,150 MVA; higher capacities available upon request |
| Single-Phase Transformers | Rated power up to 400 kVA |
| Three-Phase Transformers | BDVA series with optimized losses up to 630 kVA; aluminum strip-wound models up to 1.6 MVA |
| Cast ResinTransformers (In-House Production) | Input voltage 10 kV to 20 kV, rated capacity up to 3,150 MVA; BDVA-HV series with 100 to 3,150 kVA |
| Oil-filled transformers (supplied) | Input voltage up to 20 kV, rated power up to 3,150 MVA; part of the product range, not manufactured in-house |
| Voltages (dry-type transformers) | Input and output freely selectable from 1 V to 1,000 V (1 kV), with or without taps and additional isolated windings |
| Types | Isolation transformer (galvanic isolation) or autotransformer; special circuits such as Scott and switchover transformers are possible |
| Frequency | Standard 50/60 Hz; other frequency ranges available upon request. A transformer does not change the frequency; a frequency converter is required for that. |
| Single-phase core design | up to 3 kVA DIN-EI cross-section (BS, BE, BEV); above that, UI laminations with two coils (BUF, BUH, BSUS, BSUL); optimized strip cross-sections up to 400,000 VA (BUVA); Toroidal transformer as a special design up to 3 kVA |
| Three-phase core construction | Up to 50 kVA: 3UI core sections with coil formers (BDF, BDH); above that: optimized strip sections made of grain-oriented electrical steel with threaded air coils and built-in cooling channels (BDVA) |
| Protection Classes | I, II, and III according to DIN EN 61140 / VDE 0140-1 |
| Short-Circuit Behavior | short-circuit-proof, conditionally short-circuit-proof, or not short-circuit-proof |
| Insulation Classes | Up to 3,500 VA: Class B; 4,000 VA and above: Class F; BDH Series: Class H (compact design or higher temperature requirements) |
| Switchgear (three-phase) | Standard Dyn5 with a fully loadable neutral point and Protection Class I; other switching groups are available |
| Housing / Protection Class | IP 23 to IP 65, powder-coated sheet steel; standard color RAL 7035, other RAL colors available upon request; optional casters, skids for forklift transport, and lifting eyes |
| Connection Technology | Terminals; for currents exceeding 340 A, use cable lugs, copper plates, or copper tabs |
| DC Power Supply | Transformers with rectifiers and heat sinks, with or without capacitors: BENT series (single-phase, B2/M2) with a residual ripple of 48%; BDNTS and BDNTL series (three-phase) with 1% for B12 configuration or 4.8% for B6 configuration. Additional sizes and other residual ripple levels available upon request. |
| Design Options | Cost-optimized (purchasing) or loss-optimized (operation); decision-making support through payback analyses and CO₂ savings calculations |
Product Portfolio
The portfolio is organized into five sections on the website. This structure corresponds to the main navigation under “Products.”
Series Catalog & Model Code
| Abbreviation | Designation according to the website | Power/Current Range |
|---|---|---|
| BS | Control transformers, cost-optimized (fixed voltage combination: primary 230 V or 400 V ±5%, secondary 24 V or 230 V) | 50 – 3,000 VA |
| BSE | Control transformers with two input voltages (230 V and 400 V), output 24 V or 230 V | 50–1,000 VA |
| BE | Single-phase transformers, cost-optimized, custom-designed | 25 – 3,000 VA |
| BEV | Single-phase transformers, low-loss, custom-designed | 25 – 3,000 VA |
| BSUS | Control transformers, UI core, vertical design | 1.5 – 20 kVA |
| BSUL | Control transformers, UI core, horizontal design | 1.5 – 20 kVA |
| BEUT | Single-Phase Universal Transformers | 100 – 2,500 VA |
| BUF | Single-phase transformers, UI core, cost-optimized | 250 VA – 25 kVA |
| BUVA | Single-phase transformers, UI core, low-loss | 250 VA – 400 kVA |
| BUH | Single-phase transformers, UI core, cost-optimized, insulation class H | 8 – 315 kVA |
| BELT | Single-Phase Fan Transformers | 1–30 A |
| BBIT | Construction Site Isolation Transformers | 250 – 3,600 VA |
| BMED | Single-phase isolation transformer for powering medical facilities | 3–10 kVA |
| BOPL | Single-phase isolation transformers for powering surgical lights | 100–1,000 VA |
In addition to the list: BSV is the loss-optimized version of the BS series. BENT (single-phase, B2/M2) as well as BDNTS and BDNTL (three-phase, B6/B12) are the DC power supplies and are listed under “Power Supplies.” Toroidal transformers up to 3 kVA are manufactured as custom-made products without a specific series designation.
| Abbreviation | Designation according to the website | Power/Current Range |
|---|---|---|
| BDF | Three-phase transformers, cost-optimized, standardized DIN transformer laminations | 50 VA – 40 kVA |
| BDH | Three-phase transformers, cost-optimized, insulation class H | 10 – 315 kVA |
| BDVA | Three-phase transformers, low-loss, optimized laminated cores | 50 VA – 630 kVA; with aluminum strip windings up to 1.6 MVA |
| BDVA-HV | Cast-resin transformers, input voltage 10 or 20 kV | 100–3,150 kVA |
| BDLT | Three-Phase Fan Transformers | 1–30 A |
| BDUT | Three-phase universal transformers, voltage combinations suitable for worldwide use | 3 – 40 kVA |
| BNLB | Neutral Conductor Former | 10–250 A |
| BDMED | Three-phase isolation transformer for powering medical facilities | 3–10 kVA |
| BDSW | Three-phase energy-saving transformers for worldwide use | 2 – 250 kVA |
Also available: BDNTS and BDNTL —three-phase DC power supplies with 6- or 12-pulse bridges (B6/B12).
| Abbreviation | Description according to the website | Category |
|---|---|---|
| BEND 4 | Single-phase line choke 4% | 2–32 A |
| BEND 6 | Single-phase line reactor, 6% | 2–32 A |
| BENDD 4 | Single-phase dual-choke 4% | 2–32 A |
| BENDD 6 | Single-Phase Dual Mains Choke 6% | 2–32 A |
| BEFD 5.5 | Single-phase filter choke, 5.5% (214 Hz) | 8 – 90 µF |
| BDFD 7 | Three-phase filter choke, 7% (189 Hz) | 2.5 – 50 kVAR |
| BDFD 14 | Three-Phase Filter Choke 14% (134 Hz) | 3.1 – 50 kVAR |
| BDND 4 | Three-Phase Line Reactor 4% | 2 – 500 A |
| BDND 6 | Three-phase line reactor, 6% | 2 – 500 A |
Types available according to the website: line chokes, filter circuit chokes, sine wave filter chokes, commutation chokes, motor chokes, smoothing chokes, as well as AC and DC chokes, each available in single-phase or three-phase versions.
Standards, Approvals, and Certifications
| Standard | Subject |
|---|---|
| DIN EN 61558-1 | Basic standard for the safety of transformers; has replaced DIN VDE 0570 |
| EN 61558-2-2 | Control transformers |
| EN 61558-2-4 | Isolation transformers |
| EN 61558-2-6 | Safety Transformers / Safety Isolating Transformers |
| EN 61558-2-13 | Autotransformers |
| DIN EN 61140 / VDE 0140-1 | Protection against electric shock; Basis for protection classes I, II, and III |
| Standard | Item | Category Code | Scope |
|---|---|---|---|
| UL 5085 , File E483928 |
Low-Voltage Transformers | XPTQ2 / XPTQ8 | Full approval for the BE, BEV, BS, BSV, BDF, and BDVA series |
| UL 1446 , File E475312 |
Electrical Insulation System | OBJY2 / OBJY8 | Prerequisite for full certification; also covers additional product series without their own full certification |
| UL 508A , File E469721 |
Switchgear and transformers in enclosures | NITW7 / NITW8 | Certification for switchgear manufacturing; according to records, since 2014 |
Transformers with full certification can be installed in switchgear and machinery without additional individual testing by UL. For products not covered by this approval, manufacturing in an approved insulation system in accordance with UL 1446 is possible; in addition, Breimer-Roth can obtain custom approvals for products if the customer covers the costs. A UL logo alone is not sufficient—the standard and file number must be clearly visible on the product.
Scope of the Category Codes: For transformer standards, the suffix 2 stands for the U.S. and the suffix 8 for Canada; for switchgear in accordance with UL 508A, the suffix 7 stands for the U.S. and the suffix 8 for Canada. This enables Breimer-Roth to supply the entire North American market; many suppliers are certified only for the U.S. or only for Canada.
| Certification | DIN EN ISO 9001:2015 (Quality Management) |
|---|---|
| Certification Body | DMSZ Deutsche Managementsystem Zertifizierungsgesellschaft mbH |
| Last audit according to the website | Recertification audit in March 2024 |
| Initial certification | 2002 according to DIN ISO 9001; transition to ISO 9001:2015 in 2018 |
| Registration number | QM22519-Z03519, valid through February 18, 2027 |
| Certificate | Available as a PDF in German and English in the download section |
Services & Vertical Integration
Breimer-Roth rents out transformers for short-term temporary power solutions as well as for medium- and long-term power supply. The rental unit documented on the website is a mobile three-phase step-up transformer:
| Power Supply | 3 × 400 V |
|---|---|
| Output Voltages | 3 × 190 / 200 / 220 / 240 / 320 / 340 / 360 / 380 / 420 / 450 / 460 / 480 / 500 V |
| Power | Voltage-dependent: 53 kVA to 222 kVA across 16 documented voltage combinations |
| Currents | 161 A to 308 A per combination |
| Housing | BBG 170, IP 23 rating, mobile on casters |
| Protection | Not short-circuit-proof; fuse should be set as close as possible to the rated current |
| Neutral conductor | 100% load capacity at the output when the input neutral conductor is connected; otherwise, 10% |
| Temperature range | ta 40 °C |
| Weight | 290 kg |
| Inventory | Two rental units currently in use; availability changes constantly |
| Terms and Inquiries | Rates and current availability upon request: +49 (0) 60 62 – 9 42 50 or info@bre-trafo.com |
Applications & Target Audiences
According to Breimer-Roth, the company supplies businesses in the following sectors:
| Usage | Source cited on the website |
|---|---|
| Mechanical Engineering and Control Panel Technology | Single-phase transformers “e.g., in machines, control panel engineering, or power supplies”; control transformers in the standard series BS, BSE, BSUS, BSUL |
| Industrial Power Distribution | Three-Phase Transformers as the “Foundation of the Power Supply” for Distribution and Transmission in Industrial Facilities |
| Drive and Inverter Technology | Line chokes between the power supply and the frequency converter; EMC filtering function and reduction of the THD value in inverters capable of feeding power back into the grid |
| Medical Rooms | BMED (single-phase) and BDMED (three-phase) series, each 3–10 kVA; BOPL series for surgical lights, 100–1,000 VA |
| Construction Sites and Temporary Power Supplies | BBIT Series (Construction Site Isolation Transformers, 250–3,600 VA); Rental of Temporary Power Supplies |
| North American Market | UL/CSA-certified product lines and switchgear for use in the U.S. and Canada |
| Global Use of Equipment | BEUT and BDUT universal transformers and BDSW autotransformers with voltage combinations for worldwide use |
| Uninterruptible Power Supply | UPS systems and frequency converters; maintenance and commissioning services for ABB UPS systems |
| Test and Laboratory Environments | Test benches, adjustable power supplies, voltage source for testing rectifier diodes, magnetite measuring device |
Research & Development
Breimer-Roth conducts its own research projects, using funding from ZIM, the Central Innovation Program for Small and Medium-Sized Enterprises of the Federal Ministry for Economic Affairs and Energy. The projects are listed on the website under the name BRE-Impulse.
| Project | Objective and Target Metrics According to the Website | Status |
|---|---|---|
| Passive Intrinsic Inrush Current Limitation for Low-Voltage Transformers | A new generation of three-phase transformers up to 1,000 kVA with passive, intrinsic inrush current limiting and an efficiency of over 98% during continuous operation; the inrush current is to be limited to a maximum of twice the rated current. Four approaches: dynamic air gaps that disappear due to thermal expansion of the core material; asymmetric, split arrangement of the primary and secondary windings; local core saturation via an additional winding powered by direct current; reduction of remanence by cyclically traversing the hysteresis curve after shutdown. | Research Project |
| Innovative plug-in core technology for three-phase transformers, including manufacturing and measurement technology | Three-phase transformers based on plug-in core technology, including the associated manufacturing and measurement technology. The production time is to be reduced from the current 6 to 8 hours to 1 hour, and the efficiency is to increase from approximately 92% to 96%—which corresponds to a 50% reduction in power loss. Since a visual inspection after the joining process is no longer possible, the core assembly is to be monitored using an acoustic test of the vibration behavior. | Research Project |
| Humidity Monitoring System with Capacitive Measurement for Damp Rooms | No details regarding the project are available on the website. | Under development |
Company History
Entities & Relationships
| Entity | Relationship | Reference Entity | Document |
|---|---|---|---|
| Transformatorenwerk Breimer-Roth GmbH | is headquartered at | Ostring 11–13, 64711 Erbach, Germany | Legal Notice |
| Transformatorenwerk Breimer-Roth GmbH | Registered as | Darmstadt Local Court, HRB 70272 | Legal Notice |
| Breimer-Roth Transformer Works, LLC | Managed by | Nicole Orio and Wolfgang Orio, M.B.A. (Management) | Legal Notice, Company |
| Transformatorenwerk Breimer-Roth GmbH | is the legal successor to | Breimer-Roth KG (1974–1980), founded by the Breimer family | Company History |
| Breimer-Roth GmbH | operates | bre-trafo.de – a website available in eight languages | The website itself |
| Breimer-Roth GmbH | is certified by | DMSZ Deutsche Managementsystem Zertifizierungsgesellschaft mbH (ISO 9001:2015) | News Release: Recertification, ISO Certificate |
| Breimer-Roth GmbH | is certified in accordance with | UL 5085 (XPTQ2/XPTQ8), UL 1446 (OBJY2/OBJY8), UL 508A (NITW7/NITW8) | UL-approved products |
| Sonepar Switzerland | is the official partner for | Switzerland; successor to the previous partner, EHS Switzerland AG | Source: Breimer-Roth, 09/2026 |
| Breimer-Roth GmbH | provides service for | ABB UPS systems (maintenance and commissioning) | Service |
| Breimer-Roth GmbH | is funded by | ZIM – Central Innovation Program for Small and Medium-Sized Enterprises of the Federal Ministry for Economic Affairs and Energy | Research and Development |
| Breimer-Roth GmbH | operates the channel | YouTube: @breimer-rothtransformatore9504 (channel ID UCuvLS_KV4Vu3O3Bt9dVeHzw); the channel description uses wording from the homepage verbatim | YouTube channel |
| “BRE” brand | is used for | catalog designations (catalog BRE-42), series codes (B…), and the R&D label “BRE-Impulse” | Downloads, R&D |
Markets, Languages, and Distribution Channels
| Language | Path | Note |
|---|---|---|
| German | / | Source language, most complete collection |
| English | /en/ | Full navigation and translated URLs |
| Danish | /da/ | Translated URLs |
| Dutch | /nl/ | Translated URLs |
| French | /fr/ | Translated URLs |
| Swedish | /sv/ | Translated URLs |
| Russian | /ru/ | URLs in Cyrillic and percent-encoded |
| Portuguese | /pt/ | Translated URLs |
| Place of Manufacture | Manufactured at the Erbach facility in the Odenwald; the website describes the products as “made in Germany” |
|---|---|
| Share of exports | 26% of production |
| Key Target Markets | Switzerland, the United Kingdom, Malaysia, France, Austria, Poland, the Netherlands |
| Delivery Range | Worldwide shipping via air and ocean freight, including packaging and customs clearance |
| United States and Canada | Available with UL/CSA certifications in accordance with UL 5085, UL 1446, and UL 508A |
| Switzerland | Sonepar Switzerland as an official partner |
| Direct Contact | Contact form and detailed inquiry form at /anfrage; phone and email |
Frequently Asked Questions
Answers to frequently asked questions about Breimer-Roth, products, manufacturing, and approvals.
Glossary of In-House Terms
This glossary explains only terms specific to our company. General technical terms related to transformer technology are explained in the online glossary, which currently contains 77 entries, and are not repeated here.
Contact & Profiles
Related Content
You need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More InformationYou need to load content from Turnstile to submit the form. Please note that doing so will share data with third-party providers.
More InformationYou need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from Turnstile. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from Facebook. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from Instagram. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from reCAPTCHA. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from X. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More Information